BCSD-66/116 Digital Brushless AC Servo Drive system - Ref. 1809
4.4.5. Speed Reference Filter Time Constant
4.4.6. S-curve Risetime
Pn308
Speed Reference Filter Time Constant Speed
Setting Range Setting Unit Factory Setting Setting Validation
0 ~ 10000 1 ms 0 Immediately
This smoothens the speed reference by applying a 1st –order delay filter to the analog speed reference (V-REF)
input. A value that is too large, however, will slow down response.
Pn309
S-curve Risetime Speed
Setting Range Setting Unit Factory Setting Setting Validation
0 ~ 10000 1 ms 0 Immediately