4
Select the I/O start addresses,
e.g.: DI = 24, DO = 24.
5
Configuration ( = equipment on valve termi-
nal)
Enter:
for each group of 8 inputs: 8DI
for each group of 8 outputs: 8DO
The entry fields must be assigned in as-
cending order without gaps. No field may
be unused. Inputs must be entered before
outputs.
Example 1:
Valve terminal with 4 x 8-input modules,
+ 12 single solenoid valves.
Configuration:
8DI, 8DI, 8DI, 8DI, 8DI, 8DO, 8DO
The 4 status bits increase the number of in-
puts to 40 in this case
(32I + 4I unused + 4 status bits).
Example 2:
Valve terminal with 10 single solenoid
valves and 6 double solenoid valves.
Configuration:
8DO, 8DO, 8DO
VIFB13 - 03/05 4. Commissioning