Electronics Manual
Field bus connection FB13
Only valid in agreement with the printed documentation
accompanying the product! Compare this edition code.
Field bus protocol:
PROFIBUS DP 12 MBaud

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the Festo FB13 and is the answer not in the manual?

Summary

Fitting Valve Terminals

2.1 Fitting the Components

Safety instructions and warnings for fitting valve terminal components.

Type 03: Fitting the Valve Terminal

Guidelines for wall mounting type 03 valve terminals, including weight calculation.

Type 05: Fitting the Valve Terminal

Guidelines for wall mounting type 05 valve terminals, including weight calculation.

Installation and Connection

3.1 General Connection Principles

Fundamental principles and safety warnings for connecting valve terminals.

Connecting the Cables to the Plugs;Sockets

Step-by-step instructions for connecting cables to plugs and sockets.

3.2 Field Bus Node

Procedures for opening, closing, and configuring the field bus node.

Configuring the Valve Terminal

Steps for configuring the valve terminal via PC boards and settings.

Setting the Station Number and Voltage Monitoring

How to set station numbers and voltage monitoring using DIL switches.

Address Selector Switches

Using address selector switches to set the station number for the valve terminal.

3.2.1 Type 03: Connecting the Operating Voltages

Specific instructions for connecting operating voltages for valve terminal type 03.

3.2.2 Type 05: Connecting the Operating Voltages

Specific instructions for connecting operating voltages for valve terminal type 05.

3.3 Connecting the PROFIBUS DP Interface

Detailed guide on connecting the PROFIBUS DP interface to the valve terminal node.

3.4 Connecting the Input Modules

Instructions for connecting digital input modules to the valve terminal.

3.5 Connecting the Output Modules

Instructions for connecting digital output modules to the valve terminal.

Commissioning Valve Terminals

4.1 Basic Principles of Configuration and Addressing

Core principles for configuring and addressing valve terminals for operation.

Switching on the Operating Voltage

Procedures and important notes for safely switching on operating voltage.

Calculating the Configuration Data

Method for calculating the required I/O configuration based on module types.

Calculating the Number of Inputs;Outputs Type 03

Detailed calculation method for inputs/outputs specific to valve terminal type 03.

Calculating the Number of Inputs;Outputs Type 05

Detailed calculation method for inputs/outputs specific to valve terminal type 05.

Address Assignment of the Valve Terminal

General guidelines for assigning addresses based on terminal fitting variants.

Example of Addressing Type 03 MIDI;MAXI Valves

Practical example showing address assignment for type 03 MIDI/MAXI valves.

Example of Addressing Type 05 ISO Valves

Practical example showing address assignment for type 05 ISO valves.

Diagnosis and Error Treatment

5.1 Summary of Diagnostic Possibilities

Overview of the diagnostic and error treatment possibilities available for the valve terminal.

5.5 Diagnosis via PROFIBUS-DP (DP-SIEMENS)

Diagnosis procedures specific to PROFIBUS-DP (Siemens) communication.

5.6 Diagnosis via PROFIBUS-DP (General DP-Master)

General diagnosis procedures for PROFIBUS-DP using a General DP-Master.

5.7 Error Treatment

How the system reacts to faults and how to perform error treatment.

Short Circuit;Overload at an Output Module

How to identify and resolve short circuits or overloads on output modules.

Summary

Fitting Valve Terminals

2.1 Fitting the Components

Safety instructions and warnings for fitting valve terminal components.

Type 03: Fitting the Valve Terminal

Guidelines for wall mounting type 03 valve terminals, including weight calculation.

Type 05: Fitting the Valve Terminal

Guidelines for wall mounting type 05 valve terminals, including weight calculation.

Installation and Connection

3.1 General Connection Principles

Fundamental principles and safety warnings for connecting valve terminals.

Connecting the Cables to the Plugs;Sockets

Step-by-step instructions for connecting cables to plugs and sockets.

3.2 Field Bus Node

Procedures for opening, closing, and configuring the field bus node.

Configuring the Valve Terminal

Steps for configuring the valve terminal via PC boards and settings.

Setting the Station Number and Voltage Monitoring

How to set station numbers and voltage monitoring using DIL switches.

Address Selector Switches

Using address selector switches to set the station number for the valve terminal.

3.2.1 Type 03: Connecting the Operating Voltages

Specific instructions for connecting operating voltages for valve terminal type 03.

3.2.2 Type 05: Connecting the Operating Voltages

Specific instructions for connecting operating voltages for valve terminal type 05.

3.3 Connecting the PROFIBUS DP Interface

Detailed guide on connecting the PROFIBUS DP interface to the valve terminal node.

3.4 Connecting the Input Modules

Instructions for connecting digital input modules to the valve terminal.

3.5 Connecting the Output Modules

Instructions for connecting digital output modules to the valve terminal.

Commissioning Valve Terminals

4.1 Basic Principles of Configuration and Addressing

Core principles for configuring and addressing valve terminals for operation.

Switching on the Operating Voltage

Procedures and important notes for safely switching on operating voltage.

Calculating the Configuration Data

Method for calculating the required I/O configuration based on module types.

Calculating the Number of Inputs;Outputs Type 03

Detailed calculation method for inputs/outputs specific to valve terminal type 03.

Calculating the Number of Inputs;Outputs Type 05

Detailed calculation method for inputs/outputs specific to valve terminal type 05.

Address Assignment of the Valve Terminal

General guidelines for assigning addresses based on terminal fitting variants.

Example of Addressing Type 03 MIDI;MAXI Valves

Practical example showing address assignment for type 03 MIDI/MAXI valves.

Example of Addressing Type 05 ISO Valves

Practical example showing address assignment for type 05 ISO valves.

Diagnosis and Error Treatment

5.1 Summary of Diagnostic Possibilities

Overview of the diagnostic and error treatment possibilities available for the valve terminal.

5.5 Diagnosis via PROFIBUS-DP (DP-SIEMENS)

Diagnosis procedures specific to PROFIBUS-DP (Siemens) communication.

5.6 Diagnosis via PROFIBUS-DP (General DP-Master)

General diagnosis procedures for PROFIBUS-DP using a General DP-Master.

5.7 Error Treatment

How the system reacts to faults and how to perform error treatment.

Short Circuit;Overload at an Output Module

How to identify and resolve short circuits or overloads on output modules.