Flexball Italiana S.r.l. 58
16. Programming of actuators with electronic motor and electronic
gearbox
16.1. Electrical wiring
For electrical wiring please refer to section 10.2.
16.2. Specific parameters
Installations with electronic gearbox might require a delay time when you pass the lever directly from reverse to
forward or from forwards to reverse. Factory setting is 0,5 seconds.
Parameter list
Display
code
Description Values Factory value
Value shown on
display (factory
value)
Note
dI
Delay in switching off
the gearbox
0 .. 9,9 s 0,0 s 00
dA Delay in start of throttle 0 .. 9,9 s 0,0 s 00
dF
Delay in neutral; it
occurs any time you
move directly from
forward to reverse or
from reverse to forward.
This delay does not
occur when from
neutral you move to
forward or reverse.
0 .. 9,9 s 0,5 s 05
L1
H1
C1
L2
H2
C2
L3
H3
C3
L4
H4
C4
These parameters are present only in system with electronic engine with ECU
and/or electric engine inverter driven. Parameters for the voltage outputs are
described at section 14.2.2.
CC To be used for the check-up of the internal CANBus communication