Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 5
Removing worm shaft assembly.
MX-40 Remove adapter plate and worm assembly
together (5a).
MX-85/140 Remove adapter plate, then remove worm assembly (5b).
NOTE: When removing the side-mounted handwheel, the inner
bearing (#13-8) should remain in place in the housing.
Rotate the handwheel assembly clockwise (CW) to withdraw the
complete worm shaft plate subassembly.
STEP 6
If needed, remove the handwheel worm gear assembly (#12).
(See Section 4.14.1 for removal procedure) MX-40.
(See Section 4.16.2 for removal procedure) MX-85/140.
4-22
Flow Control Division
Limitorque Actuation Systems
Mechanical Assemblies
5a
5b
6
Handwheel Worm
Gear Adapt. (12-1)
MX-40
MX-85/140

Table of Contents