Electronic Assemblies
Accutronix MX Maintenance & Spare Parts Manual 130-12000 Revision B • November 2002
STEP 7
Remove the control module assembly from actuator housing (leave
20-pin ribbon cable connected to control module boards). Take
control module assembly to work area to perform maintenance as
required.
If control module assembly return is required for repair/replacement,
remove the ACP board from inside the ACP cover as follows:
STEP 8
Using a 3 mm hex key, remove the four M4 screws (#8-25) that retain
the ACP board inside the ACP cover.
STEP 9
Lift the ACP board out of the ACP cover.
(See Section 5.2.3 for fuse replacement.)
(See Section 5.2.4 for control module return options.)
(See Section 5.2.5 for EPROM care and replacement.)