Franke Kaffeemaschinen AG
TD-100228 A.doc page 30 / 33
61 Chipcard ident The chipcard is invalid or unknown.
62 Chipcard ident The chipcard is invalid.
The card is not initialised or contains unknown data. Delete the
chip card (except the Install card).
63 Chipcard ident The machine number (serial number) is incorrect —> The
download card does not match the machine.
Delete the card.
81 EEPROM error An error occurred while reading. There was a checksum error
(CRC).
If after rebooting the error reoccurs, replace the CPU print.
82 EEPROM error An error occurred while writing.
If after rebooting the error reoccurs, replace the CPU print.
83 EEPROM error An error occurred while writing. EEPROM is missing or defective.
If after rebooting the error reoccurs, replace the CPU print.
84 EEPROM error An error occurred while writing.
If after rebooting the error reoccurs, replace the CPU print.
85 EEPROM error EEPROM is missing or defective.
If after rebooting the error reoccurs, replace the CPU print.
99 Water filter The water filter needs to be replaced.
Replace the water filter and delete the error by resetting the water
meter (INSTALL 6.2).
100 Empty drawer The dregs drawer must be immediately emptied. Coffee stays
blocked until this is done.
Empty the dregs drawer.
101 Drawer full The dregs drawer is full. There is only room for 10 more ‘cakes’.
Empty the dregs drawer.
110 Error flowmeter There is interference with the water flow. The error will be deleted
as soon as the flow is restored.
The pump or the flow meter are possibly defective.
120 Out of beans The coffee bean containers are empty.
Fill up with beans and press a product button or the clean button.
130 Milk empty The milk container is empty. No milk products can be dispensed.
Fill up the milk container with milk!
131 Refill milk The milk container is almost empty. The milk products specified in
INSTALL 1.25 can still be dispensed.
Fill up the milk container with milk!
160 Empty battery The back-up battery in the CPU print is missing or empty.
Replace the battery prior to the power being switched off, or else
all configured product and machine data will be lost. It is highly
recommended to save existing configurations onto the download
card.