Franke Kaffeemaschinen AG
TD-100228 A.doc page 31 / 33
161 Invalide timedatas The RTC is defective or contains incorrect time data (implausible
date/time).
Reconfigure RTC with INSTALL 3.2 & 3.3 or ADJUST 2.1 & 2.2!
Possibly the battery in the CPU print is empty or missing.
162 RTC- Power failure The RTC was dead and possibly contains incorrect data.
The CPU battery is possibly empty. See Error 160 & 161.
170 Watercont. empty The water container is empty or the waste water container full.
Fill up the water container and empty the waste water container.
A product already requested will still be dispensed
180 Menu error Incorrect procedure
181 Menu error No valid menu function available or executable. This can occur
with ADJUST B and C if all items are disabled.
The menu points can be opened with the help of the service tool.
200 Communication CCI/CSI protocol: there was no response from the billing device
within the time allowed.
The connection is possibly broken or disrupted.
201 Communication CCI/CSI protocol: the data were not transferred within the time
allowed.
The connection is possibly broken or disrupted.
202 Communication CCI/CSI protocol: the checksum of the data block is invalid.
203 Communication CCI/CSI protocol: a request was not understood by the billing
device 5 times in a row.
Check the communication, restart the machine.
210 UART 0 (X11) Interface 0: initialisation error, incorrect parity, data bits, stop bit,
baud rate.
Restart the machine.
211 UART 0 (X11) Interface 0: transmission memory overflow.
Restart the machine.
212 UART 0 (X11) Interface 0: framing error.
Restart the machine.
213 UART 0 (X11) Interface 0: parity error.
Restart the machine.
214 UART 0 (X11) Interface 0: receive memory overflow.
Restart the machine.
220 UART 1 (X10) Interface 0: initialisation error, incorrect parity, data bits, stop bit,
baud rate.
Restart the machine.
221 UART 1 (X10) Interface 0: transmission memory overflow.
Restart the machine.
222 UART 1 (X10) Interface 0: framing error.
Restart the machine.
223 UART 1 (X10) Interface 0: parity error.
Restart the machine.
224 UART 1 (X10) Interface 0: receive memory overflow.
Restart the machine.
245 Machine ON Info
246 Machine OFF Info
250 Cleaning started Info: Cleaning cycle was started
251 Cleaning interrupted Info: Cleaning cycle was interrupted