Foreword and safety instructions
Safety
Protective meas-
ures against ESD
Fronius Technical
Support
Please contact your national Fronius Technical Support team with any fault analysis que-
ries.
Ordering spare
parts
Please contact your national Fronius Technical Support team to order spare parts or to
consult on fault analysis queries.
General The service manual can be obtained from the DownloadCenter at "downloadcenter.froni-
us.com".
Each chapter in the service manual deals with one complete topic. Use each chapter as a
self-contained source of information. A short description of each chapter follows.
Tools and meas-
uring devices
This provides an overview and description of all equipment required for servicing the de-
vice professionally. This equipment includes:
- Tools required
- Measuring and testing equipment
- Ancillary materials
WARNING! Work that is carried out incorrectly can cause serious injury and dam-
age. All activities described in the service manual must only be carried out by Fro-
nius-trained service technicians. Take note of the "Safety rules" section in the
inverter operating instructions.
WARNING! An electric shock can be fatal. Before opening the device:
- Move the mains switch to the O position
- Unplug the device from the mains
- Put up an easy-to-understand warning sign to stop anybody inadvertently
switching it back on again
- Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have been discharged.
WARNING! An electric shock can be fatal. If the device needs to be switched on
briefly for testing while the housing is open:
- Do not touch any parts inside the housing
- Only touch using suitable measuring or test probes
WARNING! An inadequate ground conductor connection can cause serious inju-
ry or damage. The housing screws provide a suitable ground conductor connec-
tion for earthing (grounding) the housing and must NOT be replaced by any other
screws which do not provide a reliable ground conductor connection.
Danger of damage to electrical components from electrical discharge. Suitable
measures should be taken to protect against ESD when replacing and install-
ing components.

Table of Contents

Other manuals for Fronius Symo

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo and is the answer not in the manual?

Fronius Symo Specifications

General IconGeneral
THD< 3 %
Number of MPP Trackers2
Protection ClassIP65
Frequency Range50 / 60 Hz
Operating Temperature Range-25°C to +60°C
Power Range3.0 kW - 20.0 kW
AC Output Voltage230 V
CommunicationEthernet
Warranty5 years
ModelSymo

Related product manuals