Unit: kJ
Setting range: ON / OFF
Factory setting: OFF
Since the full range of values (1 kJ - 99999 kJ) cannot be displayed on the three-
digit display, the following display format has been selected:
Value in kJ: 1 to 999 / indicator on display: 1 to 999
Value in kJ: 1000 to 9999 / indicator on display: 1.00 to 9.99 (without unit digit,
e.g., 5270 kJ -> 5.27)
Value in kJ: 10,000 to 99,999 / indicator on display: 10.0 to 99.9
(without unit digit or tens digit, e.g., 23580 kJ -> 23.6)
ALC Arc length correction display
(For setting how the arc length correction parameter is displayed)
Setting range: ON / OFF
Factory setting: OFF
Set to ON if the welding voltage parameter is selected and set on the con-
trol panel
- The left-hand display shows the arc correction value for three seconds
- The right-hand display shows the value for the welding voltage at the same
time
Parameters for
TIG welding
SEt Country-specific setting (Standard/USA) ... Std/US
Unit: -
Setting range: Std, US (Standard/USA)
Factory setting:
Standard device: Std (measurements in cm/mm)
USA device: US (measurements: inches)
FUS Mains fuse protection
The maximum possible welding power is limited by the rating of the mains fuse
protection used.
Unit: A
The available mains fuse ratings are determined by the SEt parameter setting:
SEt parameter set as Std: OFF / 10 / 13 / 16
SEt parameter set as US: OFF / 15 / 20 (only for 120 V grid voltage)
Factory setting: OFF
Parameters for
stick welding
(SMAW)
SEt Country-specific setting (Standard/USA) ... Std/US
Unit: -
Setting range: Std, US (Standard/USA)
Factory setting:
Standard device: Std (measurements in cm/mm)
USA device: US (measurements: inches)
r Welding circuit resistance (in mOhm)
See section Measuring the welding circuit resistance (stick welding) from
page 108