Setup Menu Level 1
Accessing and
exiting the Setup
menu, changing
parameters
Accessing the Setup menu is described with reference to the MIG/MAG standard syner-
gic (SYNERGIC) welding process.
Access is the same for the other welding processes.
Accessing the Setup menu:
1
Press the "Process" button to select the
SYNERGIC welding process
2
The control panel is now located in the
Setup menu of the "MIG/MAG standard
synergic welding" process - the last selec-
ted setup parameter is displayed.
To change a parameter:
1
Select the desired setup parameter using
the left-hand selection dial
Change the setup parameter value using
the right-hand selection dial
To exit the Setup menu:
1
Parameters for
MIG/MAG Stand-
ard Manual Weld-
ing
GPr Gas pre-flow time
Unit: seconds
Setting range: 0 - 9.9
Factory setting: 0.1
GPo Gas post-flow time
Unit: seconds
Setting range: 0 - 9.9
Factory setting: 0.5
Fdi Feeder inching speed
Unit: m/min (ipm)
Setting range: 1 - 18.5 (39.37 - 728.35)
Factory setting: 10 (393.7)
IGc Ignition current
Unit: Ampere
Setting range: 100 - 390
Factory setting: 300