Connections, Switches, and Mechanical Compon-
ents
Safety
WARNING!
Danger from incorrect operation and work that is not carried out properly.
Serious personal injury and damage to property may result.
▶
Read and understand this document.
▶
Read and understand all the Operating Instructions for the system components,
especially the safety rules.
Front and rear of
the power source
CO² 100%
Ar+ 15-20% CO²
Ar + 2.5%CO²
Steel
CuSi
CrNi
Self-shielded
Metal cored
Rutil FCW
0,6
.023
.030
0,8
.035
0,9
.040
1,0
.045
1,2
2T
4T
S4T
MANUAL
SYNERGIC
STICK
TIG
Ar 100%
(2)
(3)
(1)
(4)
(5)
(6)
(1) Welding torch connection
For connecting the welding torch
(2) (-) Current socket with bayonet
latch
Used for
- Connecting the grounding
cable or polarity reverser for
MIG/MAG welding (depending
on the wire electrode used)
- Connecting the electrode
cable or grounding cable for
manual metal arc welding
(depending on the type of
electrode used)
- Connecting the TIG welding
torch
(3) TMC connection (TIG Multi Connector)
For connecting the TIG welding torch
(4) (+) Current socket with bayonet latch
Used for
- Connecting the polarity reverser or grounding cable for MIG/MAG welding
(depending on the wire electrode used)
- Connecting the electrode cable or grounding cable for manual metal arc
welding (depending on the type of electrode used)
- Connecting the grounding cable for TIG welding
(5) Ventilation openings (air outlet vents)
For device cooling
(6) Polarity reverser
For selecting the welding potential on the MIG/MAG welding torch
38