Displaying the welding circuit inductivity
General The way that the hosepack is arranged has a very significant effect on the welding circuit
inductivity and therefore affects the welding process. It is important to lay the hosepacks
correctly in order to obtain the best possible welding result.
Displaying the
welding circuit
inductivity
The setup parameter "L" is used to display the most recently calculated welding circuit
inductivity. The welding circuit inductivity is adjusted when the welding circuit resistance
is measured. Detailed information in this regard can be found under the "Welding circuit
resistance" chapter.
1
Access the Setup menu 2nd level (2nd)
2
Select parameter "L"
The most recently calculated welding circuit inductivity L is shown on the right-hand
digital display.
L ... Welding circuit inductivity (in microhenrys)
109