Control Panel
General As a result of software updates, you may find that there are functions available on your
device that are not described in these Operating Instructions, or vice versa.
Certain illustrations may also differ slightly from the actual controls on your device, but
these controls function in exactly the same way.
Safety
WARNING!
Danger from incorrect operation and work that is not carried out properly.
Serious personal injury and damage to property may result.
▶
Read and understand this document.
▶
Read and understand all the Operating Instructions for the system components,
especially the safety rules.
Control panel
(1) Spot welding indicator
The spot welding indicator lights up if:
- Spot welding/stitch welding mode is selected
- The SPt parameter (spot welding time/stitch welding time) in the Setup menu
is not set to OFF
(2) 2-step stitch welding indicator
The 2-step stitch welding indicator lights up if:
- Spot welding/stitch welding mode is selected and
- The SPb parameter (spot welding/stitch welding pause time) is set to a value
greater than 0 and
- The Int (interval) parameter is set to 2T
(3) 4-step stitch welding indicator
The 4-step stitch welding indicator lights up if:
- Spot welding/stitch welding mode is selected and
- The SPb parameter (spot welding/stitch welding pause time) is set to a value
greater than 0 and
- The Int (interval) parameter is set to 4T
31