6
It is only necessary to connect the mains
cable to the power source for multivoltage
power sources.
7
CAUTION!
Danger due to welding processes start-
ing unintentionally.
Personal injury and damage to property
may result.
As soon as the power source is
switched on, ensure that the tungsten
electrode does not accidentally, or in
an uncontrolled manner, touch any
electrically conductive or grounded
parts (e.g., the housing, etc.).
TIG welding
1
Press the "Process" button to select TIG
2
Set the desired welding current
When using a welding torch with a torch trigger and TIG Multi Connector plug
(with 2-step mode factory setting):
3
Position the gas nozzle at the ignition point so that there is a distance of approxim-
ately 2 to 3 mm (0.078 to 0.118 in.) between the tungsten electrode and the work-
piece
4
Gradually tilt the welding torch up until the tungsten electrode touches the workpiece
5
Pull back the torch trigger and hold it in this position
- Shielding gas flows
6
Raise the welding torch and rotate it into its normal position
- The arc ignites
7
Carry out welding
3 4 6