MHT258a (Engl.)5-54
5.7.9 Dynamic braking
This signal is output when the amplifier detects major fault.
This signal is turned on when such a major fault has occurred that the amplifier cannot drive the motor, and is retained until alarm reset
signal is input.
Dynamic braking is a braking type to short-circuit the coils between three phases of a synchronous motor to generate power.
Once the motor is stopped, braking force is not retained.
The output terminal of dynamic braking is +30V DC, 50mA. This cannot directly close a magnetic contactor. Use a general purpose relay or
FUJI SSC (solid state contactor).
Interface
Parameter setting
To allocate the dynamic braking signal to the control output terminal, set (15) to the system para.
Related items
Major fault
Fault that cannot drive motor
Dynamic braking (15)
ON : Major fault is detected
OFF : In normal operation
Minor fault
Protection against overheat etc.
+24V
Indication Detection contents
Overload
Overspeed
Overvoltage
Encoder error
Encoder communication error
Control power error
Memory error
Undervoltage
Overcurrent
Combination error
Resistor heat 2
CONT signal error
System error
Indication Detection contents
Resistor overheat
Deviation over
Amplifier overheat
Encoder overheat
ABS data lost
Multiple rotation overflow
Bus communication error