MHT258a (Engl.)8-6
8.3 Control input signal
Carry out a test running using the control input signals.
Turn off power and connect the control input/output wiring to CN1.
(1) Control input signals
In the monitor mode of the touch panel, control input signal ON/OFF can be checked.
Key input LC display (example) Remark
Example of test running mode display
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
The MODE key selects a mode.
MODE
MODEMODE
MODE
ESC
ESCESC
ESC
Select the monitor mode.
By ∧ key or ∨ key, select [On012]
SHIFT
SHIFTSHIFT
SHIFT
ENT
ENTENT
ENT
Holding down the ENT key for at least 1 [sec] allows to check the input
signal ON/OFF.
If a control input signal on CN1 turns ON, the corresponding LED lights.
The input signal display [On012] in the monitor mode is updated in real-time.
Remark : CN1 is not factory assigned to the following signals.
• Forced stop (10) • +OT (7)
• External fault input (34) • -OT (8)
These signals are N.C. (or “b”) break contact. Connecting the CN1 allows to run the motor.
At the factory set status, the amplifier carried out a speed control.
Assign a position control (37) for position control by pulse train, etc., or a torque control (38) for torque control.
These signals can be validated at all times by assigning the system para. 87 or 88.
[CONT8]・・・・・[CONT3][CONT2][CONT1]
(Positioncontrol) [REV] [FWD] [RUN]