MHT258a (Engl.)6-23
6.4 Communication
This section explains the communication setting for amplifier.
6.4.1 Station number
Sets the station number about communication.
System parameter 96
Para. Name Setting range Initial value Change
96 Station number 1 to 31 (In increments of 1) 1 Power
Specifies the amplifier station number at 1 through 31 in decimal.
If the station number is hexadecimal, see the following conversion table.
Station No. setting
(decimal)
Station No. setting
(hexadecimal)
Station No. setting
(decimal)
Station No. setting
(hexadecimal)
Station No. setting
(decimal)
Station No. setting
(hexadecimal)
1 01H 11 0BH 21 15H
2 02H 12 0CH 22 16H
3 03H 13 0DH 23 17H
4 04H 14 0EH 24 18H
5 05H 15 0FH 25 19H
6 06H 16 10H 26 1AH
7 07H 17 11H 27 1BH
8 08H 18 12H 28 1CH
9 09H 19 13H 29 1DH
10 0AH 20 14H 30 1EH
31 1FH
6.4.2 Baud rate
Specifies the RS485 interface baud rate. This baud rate is different from that of the exclusive loader or PC loader.
System parameter 97
Para. Name Setting range Initial value Change
97 Baud rate 0 : 9600[bps]
1 : 19200[bps]
2 : 38400[bps]
0 Power