MHT258a (Engl.)2-12
(c) 0.05 to 0.2 [kW] for 100 [V] class input voltage of amplifier
Amplifier type RYS□□□S3-VVS6 500 101 201
Applicable motor output (*1) [kW] 0.05 0.1 0.2
Phase, freq. Single-phase for power supply, single-phase for control, 50/60 [Hz]Input
Voltage 100 to 115 [V], +10 to −15[%]
System Sinusoidal PWM current control (all digital)
Carrier freq. [kHz] 10
Feedback 16-bit serial encoder (one-revolution resolution 16-bit, multi-revolution 16-bit)
Loading for 0 to 100 [%] deviation
Supply volt.
±1 [r/min]
max.
For −10 to +10 [%] fluctuation
Speed
control
accuracy
Amb. temp. ±15 [r/min] max. for −10 to +55 [°C] variation (at analog volt. input)
Speed range 1 : 5000 (at rated load)
Freq. response 500 [Hz] (at J
L
= J
M
(*2) )
Load inertia. max. 100 times of the motor rotor inertia, permissible
Control
data
Overload capability 300 [%] for 3 [sec], 450 [%] for 1.5 [sec]
Braking Regenerating, dynamic with external braking resistor
Protection OC (output overcurrent), OS (overspeed), L
V
(low voltage, undervoltage),
H
V
(high voltage, overvoltage), Et (encoder trouble), Ct (circuit trouble, amplifier trouble),
dE (data error, memory error), CE (combination error), rH
2
(resistor heat 2),
EC (encoder communication error), CtE (cont (control signal) error),
OL (motor overload), rH (resistor heat, braking (OB) resistor overheat),
OF (over flow, deviation excessive), AH (amp. heat, amplifier overheat),
EH (encoder heat, encoder overheat), AL (absolute data lost),
AF (absolute data over flow) , SE (system error)
Function
Display, setting CHARGE (red), 7-segment LED with 5-digit and 4 operation keys
Installation place For indoors, 1000 [m] and below of site-altitude, under clean atmosphere,
no explosive hazardous gas and vapour is existing.
In the case of compliance with the European standard :
Pollution degree = 2, Over voltage category = Ⅱ
Temp., humidity −10 to +55 [°C], 90 [%] RH max. (free from condensation)
Ambient
condition
Vibration / shock 4.9 [m/s
2
] / 19.6 [m/s
2
] acceleration, acceptable (max.)
Others DC reactor terminals (P1, P+) for higher harmonics suppression.
UL/cUL (compliance with UL508), European standards (compliance with EN50178)
Mass (weight) [kg] 0.9 1.2
(*1)
(*2)
See footnote of