MHT258a (Engl.)8-3
(3) Absolute system [ABS]
If an absolute system is used, carry out a start up in the following procedure.
(a) Battery
Install a battery (WSB-S type) on the amplifier as follows.
(i) Pull open downward the cover for the battery space located
on the right side of amplifier.
(ii) On the left of the battery space, there is a connector which is
to be engaged with the connector provided for the battery.
(iii) Engage the connectors and close the cover in place.
(b) System para.
Turn on the power supply, and system para. 99 sets to “1”.
(c) Turning off power
To validate the set value of system para. 99, turn off and on power.
Make sure the CHARGE LED is extinguished (goes out) when turning
on again.
(d) Power supply
Supplying power produces an alarm “Absolute data lost”.
(e) Resetting the detected alarm
Execute the position preset [Fn003] in the test running mode to
reset the alarm.
Thereafter, the ABS system is validated.
Battery coverConnector