7-8 MHT258a (Engl.)
(4) Alarm history
The last 9 times of alarm detection history can be indicated. The indication can be scrolled by the key and key.
                                   
Alarm history indication (A)
Detected history number (1:latest, 9:oldest) Alarm code (See (3) .)
Remark : The alarm history can be deleted by trial operation mode [ ].
Press the key and key simultaneously for 1s or more while alarm detection is indicated to reset the alarm detection.
(5) Amplifier setting
The amplifier control function and connecting form are indicated.
Control function (1
st
digit, left end digit) Main control connector (2
nd
digit)
Indication Function Indication Function
Speed control DI/DO standard
Rotation indexing (dividing) SX bus
Linear positioning
Extension connector 1 (3
rd
digit) Extension connector 2 (4
th
digit)
Indication Function Indication Function
Not mounted Not mounted
DI/DO extension T-link
RS-485 Parallel
ANY bus
Multi bus
∧,∨
ENT (1s or more)
ESC
ENT (1s or more)
ESC