EasyManua.ls Logo

Fuji Electric RYS...S3-VVS Series - Output Signal; Load Inertia Ratio

Fuji Electric RYS...S3-VVS Series
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT258a (Engl.)7-14
(13) Output signal
Displays whether the control output signals from the amplifier are turned on or off. If signals are turned on, corresponding LEDs are lit.
Note : Depending on the amplifier type, the number of control output signals changes.
(14) Load inertia ratio
Displays the load inertia ratio recognized by the amplifier regardless of the tuning method (basic para. 31)
()
()
()
Loadinertia ratio
Moment of inertiarecognizedby amplifier
Moment of inertia of motor
=
Displays the magnification (in 0.1 times unit) of the moment of inertia of the motor.
Pressing the MODE key holding down the
SHIFT key interchanges the H side and L side.
ENT (1s or more)
ESC
[OUT24]・・・・・・・・・・・・・・・[OUT18] [OUT17]
[OUT32]・・・・・・・・・・・・・・・・・・[OUT26] [OUT25]
[OUT8]・・・・・・・・・・・[OUT2] [OUT1]
[OUT16] ・・・・・・・・・[OUT10] [OUT9]
ENT ( 1s or more )
EST