MHT258a (Engl.)10-3
10.1 Cables
Power supply and control circuit cables in the internal of the control panels are as follows :
(1) Power supply and motor input cables
(a) Cable size
Input voltage class [V] 100 200
Amplifier output [kW] 0.05 to 0.2 0.03 to 0.4 0.75 to 1.5 2, 3 4, 5
VVS6 VVSAmplifier type RYS□□□S3-
500 to 201 300 to 401 751 to 152 202, 302 402, 502
Power supply, motor
input, ground (earth)
1.25 2 3.5 5.5
Brake 1.25
Conductor
sectional
area of cable
[mm
2
]
Power supply for control 0.75
(b) Cable type
(i) 600V class, poly-vinyl insulated cable (JIS C 3307) or
(ii) Poly-vinyl insulated cable “KIV” (JIS C 3316) or
(iii) 600V class, cross-link polyethylene insulated cable “FSCL” (JCS 360)
or equivalent
(2) Control input/output cables for CN1 : + 24 [V], 50 [mA] max.
(a) Cable size
18-core twisted-pair shielded cable. AWG No.26
(b) Cable type
“XEBV” or “XEWV” (The Furukawa Electric Co. , Ltd.) or equivalent
(3) Host interface for CN3
(a) Digital input/output and analog signal cable : Same as (2) above.
(b) T-link, JPCN-1 and SX bus : Specified cables should be applied.
(4) Encoder cables for CN2 (4Mbps serial communication)
Cross-link polyethylene insulated, poly-vinyl sheath cables RMCV-SV type :
Wiring length within Cable size and pair, core quantities (*)
10 [m] AWG No.25 / 4-pair and AWG No.23 / 2-core
50 [m] AWG No.25 / 4-pair and AWG No.17 / 2-core
or optional cable : See 10.8.
(*) AWG : Refer to Remark of 4.3 (2) (d).