EasyManua.ls Logo

Fuji Electric RYS...S3-VVS Series - Micrex-Sx; Control Block Diagram

Fuji Electric RYS...S3-VVS Series
251 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
MHT258a (Engl.)11-15
(2) MICREX-SX
FB (function block) for acquiring a current position output (see 5.4.5).
RD_REQ : Request current position read [BOOL]
RD_ANS : Answer current position read [BOOL]
ANS_BIT1 : Amplifier data bit 1 [BOOL]
ANS_BIT2 : Amplifier data bit 2 [BOOL]
RD_COM : Read command to amplifier [BOOL]
RD_RUN : Reading [BOOL]
RD_OK : Normal end of read [BOOL]
RD_NG : Abnormal end of read [BOOL]
ABS_POS : Current position data [DINT]
Turning on RD_REQ executes a sequence of current position acquisition.
The current position is outputted in [DINT] form to ABS_POS terminal.
Connect each terminal to the amplifier.
RD_COM : Current position output command (control assign No. 56)
RD_ANS : OUT2
ANS_BIT1 : OUT3 of amplifier terminals
ANS_BIT2 : OUT4
11.3 Control block diagram
The control block diagram for RYS-V type amplifier is shown on the next page.
(1) Override
Validated by assigning the control assign terminals [CONTn] to signals.
Set value, value set at system para. No. Signal name
43 Override valid
44 Override 1
45 Override 2
46 Override 4
47 Override 8
(2) Manual feed
The speed of manual forward or reverse revolution can be selected from 8 levels.
X3 X2 X1 Speed
OFF OFF OFF NREF terminal (speed command voltage)
OFF OFF ON 1
OFF ON OFF 2
OFF ON ON 3
ON OFF OFF 4 of manual feed speed (basic para.)
ON OFF ON 5
ON ON OFF 6
ON ON ON 7
Validated by assigning the signals to control assign terminals [CONTn]
Signal function No. Functional name
51 X1
52 X2
53 X3
RD_COM
RD_RUN
RD_OK
RD_NG
ABS_POS
RD_REQ
RD_ANS
A
NS_BIT1
A
NS_BIT2
ABS_ENC_1
ABS_ENC

Table of Contents