6-20 MHT258a (Engl.)
6.3.4 Storage at RAM
The contents of basic parameter setting can be stored in built-in RAM and rewritable infinitely.
System parameter 22 to 30
Para. Name Setting range Initial value Change
22 Parameter RAM storage 1 0: Not specified 1 to 99: Basic para. No. 0 Power
23 Parameter RAM storage 2 0: Not specified 1 to 99: Basic para. No. 0 Power
24 Parameter RAM storage 3 0: Not specified 1 to 99: Basic para. No. 0 Power
25 Parameter RAM storage 4 0: Not specified 1 to 99: Basic para. No. 0 Power
26 Parameter RAM storage 5 0: Not specified 1 to 99: Basic para. No. 0 Power
27 Parameter RAM storage 6 0: Not specified 1 to 99: Basic para. No. 0 Power
28 Parameter RAM storage 7 0: Not specified 1 to 99: Basic para. No. 0 Power
29 Parameter RAM storage 8 0: Not specified 1 to 99: Basic para. No. 0 Power
30 Parameter RAM storage 9 0: Not specified 1 to 99: Basic para. No. 0 Power
The contents of basic parameter is stored in the EEPROM (electrically erasable program read only memory) for retaining purpose at power
shut down. By specifying RAM, infinite rewriting is enable.
Set the basic para. number to be stored in RAM at the system para. 22 to 30.
6.3.5 Keypad panel
The contents of indication on the keypad panel at power on can be changed.
System parameter 89
Para. Name Setting range Initial value Change
89 Initial indication 0 to 20 (in increments of 1) 0 Power
Setting Initial indication Setting Initial indication
0
[
]
Sequence 7
[ ]
Feedback speed
1
[
]
Sub mode 8
[ ]
Command speed
2
[
]
Alarm detection 9
[ ]
Actual torque
3
[
]
Alarm history 10
[ ]
Feedback position
4
[
]
Amplifier setting 11
[ ]
Command position
5
[
]
Motor setting 12
[ ]
Deviation amount
6
[
]
Station No. indication 13
[ ]
Cumulated pulse
14
[
]
Peak torque
15
[
]
Input voltage 1
16
[
]
Input voltage 2
17
[
]
LS-Z pulse
18
[
]
Input signal
19
[
]
Output signal
20
[
]
Load inertia ratio