3-12 MHT258a (Engl.)
(c) With providing speed reduction gear unit, gear ratio 1/9
GYC101 to 502DC1-S type, and gear head, 0.1 to 5 [kW]
CR CS
Φ
S
Φ
L
A
φLB
L
LL LR
LE
□LC
QK
□60
300±30
300±30
S
H
A
F
T
E
X
T
E
N
S
I
O
N
U
W
T
4-M5×12DEPTH
(*1)
Φ
S
Φ
L
A
φLB
L
LL LR
LE
□LC
QK
□60
300±30
300±30
SHAFT
EXTENSION
U
W
T
4-M6×15DEPTH
(*1)
CT CU
Φ
S
Φ
L
A
φLB
L
LL LR
LE
□LC
QK
□60
300±30
300±30
SHAFT
EXTENSION
U
W
T
4-M8×20DEPTH
(*1)
Φ
S
S
H
A
F
T
E
X
T
E
N
S
I
O
N
U
W
T
Φ
L
A
φLB
L
LL LR
LE
□LC
QK
102
65
4-M10×20DEPTH
(*2)
(*1)
Type
GYC
Fig Q QK QR φSTUW(*1) L LL LR LG LE φLA φLB
101DC1-S CR - 15 - 12
+0
-0.011
4 2.5 4 M4x8 178 153 25 - 4 60 50
+0
--0.025
201DC1-S CS - 23 - 19
+0
-0.013
6 3.5 6 M5x13 218 181 37 - 6 90 70
+0
--0.03
401DC1-S CS - 23 - 19
+0
-0.013
6 3.5 6 M5x13 233 196 37 - 6 90 70
+0
--0.03
751DC1-S CT - 30 - 24
+0
-0.013
7 4 8 M6x15 282.5 233.5 49 - 8 115 90
+0
--0.035
102DC1-S CU - 45 - 32
+0
-0.016
8 5 10 M6x15 362.5 298.5 64 - 8 135 110
+0
--0.035
152DC1-S CU - 45 - 32
+0
-0.016
8 5 10 M6x15 416.5 339.5 77 - 20 160 130
+0
--0.04
202DC1-S
302DC1-S
402DC1-S
502DC1-S
(*1) Screw hole of shaft extension
(*2) For 152 type, 1.5 [kW] : 4 - M12 × 24 DEPTH
(** ) Insulating protection tube
(** ) (** )
(** )