Troubleshooting and tips
A26391-K124-Z100-1-7619 81
Invalid system disk - Replace the disk, and then press any key
The inserted disk is not a system disk or the inserted system disk is defective.
Ê Insert another system disk.
Ê Press any key to continue.
If you wish to boot from floppy disk:
Ê Insert a system disk.
Ê Press any key to continue.
Extended memory failed at offset: xxxx Failing Bits: zzzz zzzz
When testing the extended memory an error has resulted at the address xxxx.
Ê Check whether the additional memory module has been inserted correctly.
Should you receive this error message again, please contact your dealer.
Failure Fixed Disk n
The settings of the hard disk drive are incorrect.
Start BIOS Setup and select the correct settings for Internal Hard Disk, Left Bay, Right Bay.
Fixed Disk address conflict Diskette Drive address conflict
There is an I/O address conflict.
Ê Start the BIOS Setup and check the corresponding settings.
Keyboard controller error
Ê Switch off the workstation with the Suspend/Resume button.
Ê Wait 3 - 5 seconds and switch on the workstation again.
If this error message appears again, please contact your point of sale or our Hotline/Help Desk.
Keyboard error
If you use an external keyboard:
Ê Check the connection and reboot the workstation.
If this error message appears again, please contact your point of sale or our Hotline/Help Desk.
nn Stuck key
Ê Make sure that no key is pressed.
If this error message appears again, please contact your point of sale or our Hotline/Help Desk.
Operating system not found
Ê Check in the BIOS Setup whether your hard disk has been set correctly.
Ê Make sure that the operating system is installed on the corresponding drive.
Press <F1> to resume, <F2> to SETUP.
This error message appears if an error occurs during the self-test before starting the operating
system.
Ê Press the [F1]
[F1][F1]
[F1] function key to start the operating system.
Ê Enter the BIOS Setup programme by pressing [F2]
[F2][F2]
[F2].