(5) Click the [OK] button.
The SNMP Agent basic settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen display returns to the [Network] screen.
3 Set up the SNMP Manager.
Set up the SNMP Manager (monitoring server) that is the destination of the SNMP Trap transmission.
This step is not required when ETERNUS SF Storage Cruiser is used to monitor the ETERNUS AF.
(1) In [Action], click [Setup SNMP Manager].
The [Setup SNMP Manager] screen appears.
(2) In the manager list of the [Setup SNMP Manager] screen, click the [Add] button.
The [Manager] screen appears.
(3) Enter the IP address of SNMP Manager (monitoring server) and click the [OK] button.
The screen display returns to the manager list of the [Setup SNMP Manager] screen.
(4) Check the SNMP Manager that was added in Step (3) is displayed in the manager list and click the
[Set] button.
A confirmation screen appears.
(5) Click the [OK] button.
The SNMP Manager settings are applied.
(6) Check the setting completion message and click the [Done] button.
The screen display returns to the [Network] screen.
Chapter 6 Monitoring Settings
6.2 Various Notification Settings
88
FUJITSU Storage ETERNUS AF250 S2, ETERNUS AF250 All-Flash Arrays
Configuration Guide (Basic)
Copyright 2017 FUJITSU LIMITED
P3AG-1832-04ENZ0