Using the FUNCTION Button/Setting Change Switches
This section explains how to use the FUNCTION button/setting change switches of the controller enclosure.
The following settings can be performed by using the FUNCTION button/setting change switches:
• Switching the Master CM to the other controller
Note
For the two controllers in the ETERNUS DX, the controller through which the
ETERNUS DX is set up and
operated is called the "Master CM", while the other controller is called the "Slave CM". The single-
controller type only has a "Master CM" controller.
• Restoring the factory default settings (network environment settings and firewall settings) of the LAN ports
• Restoring the factory default user settings (user account, role, and RADIUS settings)
Caution
When the user information initialization function on the operation panel is disabled with ETERNUS CLI,
the user settings do not revert to the default values even if the FUNCTION button/setting change switch
is operated.
The operating procedure for the FUNCTION button/setting change switches is described below.
1 Remove the flange cover or the front cover of the controller enclosure.
Front coverFlange co
ver
ETERNUS DX60 S5/DX100 S5/DX200 S5 ETERNUS DX500 S5/DX600 S5/DX900 S5
2 Change the status of the ETERNUS DX
to maintenance status.
Use the pin to push the FUNCTION button/maintenance switch (MNT SW) for three seconds.