EasyManua.ls Logo

Fujitsu ETERNUS DX S5 Series - Figure 25 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5;DX200 S5 Is Installed with Only One Controller)

Fujitsu ETERNUS DX S5 Series
135 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
ETERNUS DX100 S5/DX200 S5
Figure 25 Rear View of a Controller Enclosure (When the ETERNUS DX100 S5/DX200 S5 Is Installed with Only
One Controller)
7
1
2 4 5 3
8
8
63
PSU#0 PSU#1
CA#0
CM#0
CA#1
1 Controller (CM#0) (refer to "■ Controllers" (page 109))
2 PWC port
This port is used to connect a power synchronized unit with an RS232C cable.
3 Host interfaces (CA#0, CA#1) (refer to "■ Host Interface" (page 116))
4 Drive interface (OUT) port
This port is used to connect a controller enclosure to a drive enclosure with a mini SAS HD cable between
enclosures.
5 RMT (LAN) port
This port is used for connecting a LAN cable and used for separating the network (such as for the remote
support) from the MNT port for operation management. This port uses an RJ-45 connector.
6 MNT (LAN) port
This port is used for connecting a LAN cable and used for operation management. This port uses an RJ-45
connector.
7 Cover
Remove this when installing an additional controller (optional).
8 Power supply units (PSU#0, PSU#1) (refer to "■ Power Supply Units" (page 114))
A. Component Names
Controller Enclosure
100 Operation Guide (Basic)