When the READY LED Is Not On
If the following time have passed since the power of the
ETERNUS DX was turned on and the READY LED is still
not on, contact your maintenance engineer.
Table 8 Time Required for the READY LED to Turns On after Turning the Power On
Model
Deduplication/
Compression function is
disabled
Deduplication/
Compression function is
enabled
Unified configuration
(*1)
VLAN/Bonding maximum
configuration
DX60 S5 18 minutes or more
DX100 S5 18 minutes or more 40 minutes or more Approx. 50 minutes or
more
DX200 S5 18 minutes or more 22 minutes or more 40 minutes or more Approx. 50 minutes or
more
DX500 S5 18 minutes or more 25 minutes or more 42 minutes or more Approx. 53 minutes or
more
DX600 S5 20 minutes or more 28 minutes or more 44 minutes or more Approx. 55 minutes or
more
DX900 S5 (*2) 20 minutes or more 24 minutes or more
*1: The time required to turn the power on for the Unified configuration depends on the NAS configuration (or the number of shared folders
and the number of VLAN/Bonding configurations).
*2: The ETERNUS DX900 S5 supports the Compression function only.
When the FAULT LED Is On
Check the general status and the system messages in ETERNUS Web GUI. Perform the necessary actions to
correct the problem. If the problem cannot be resolved, leave the
ETERNUS DX alone and contact your
maintenance engineer.
Note
For details about how to check the general status via ETERNUS CLI, refer to "Displaying Status via ETERNUS
CLI" (page
26).
When the general status of ETERNUS Web GUI is
- Check whether one side of the mini SAS HD cable between enclosures is disconnected. If so, install the
connector in the DI port.
- Check if the mini SAS HD cable between enclosures is connected. If the mini SAS HD cable between
enclosures is not connected, use the following procedure to connect the mini SAS HD cable between
enclosures.
- Check that the l (IN) and n (OUT) side of the mini SAS HD cable between enclosures is connected correctly.
If the mini SAS HD cable between enclosures is connected incorrectly, use the procedure that is shown below
to reconnect it.