11 Turn on the
ETERNUS DX.
Refer to "Powering On" (page 18) for details on how to turn on the ETERNUS DX.
12 Check that the PORT LINK/FAULT LED for the FC port on the replaced Long wave SFP+ module (16Gbit/s)
turns off or lights up green.
13 Start ETERNUS Web GUI to check the status of the newly added Long wave SFP+ module (16Gbit/s).
On the Internal Parts information in the [Channel Adapter Details] screen of ETERNUS Web GUI, check
that the FC port status is Normal and the SFP type is changed to "16G SFP+(SMF)". In addition, confirm
that all of the other components are in normal status.
4. Component Expansion/Function Enhancement
Installing Long Wave SFP+ Modules (16Gbit/s)
66 Operation Guide (Basic)