EasyManuals Logo

Fujitsu PRIMERGY RX200 S3 User Manual

Fujitsu PRIMERGY RX200 S3
100 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #38 background imageLoading...
Page #38 background image
38 Operating Manual RX200 S3
Installing/Removing the Server in/from the Rack Hardware Installation
4.2.2 Installation in 3rd Party Racks
The following parts are required to install the server in 3rd party racks:
one left and one right telescopic rail (assembled)
M5x10 screws with integrated plugwashers
I Or, M5x10 screws with separate plugwashers can also be used.
In this case, two plugwashers each must be fitted beforehand on
the support uprights and the support bracket.
The descriptions and figures in this section refer to the current
variable support.
Ê Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.
V CAUTION!
For installation in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê Fit the required original parts (support bracket or cable management
system).
I Under certain circumstances, you will not be able to use some of the
parts from the rack installation kit supplied - you will need to use
original 3rd party rack parts instead.
Ê Remove the outer telescopic rail as described in page 36 (figure 4).
Racks with installation depth of 735 mm
The lengths of the telescopic rails do not need to be adjusted with respect to
each other for the installation in rack systems with 735 mm installation depth.
Ê Secure the telescopic rails as described in section “Mounting in the PRIME-
CENTER/DataCenter Rack” on page 35.
Ê Mount the server (see section “Inserting the server” on page 39) and route
the cables as described in the original manual of the rack.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX200 S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX200 S3 and is the answer not in the manual?

Fujitsu PRIMERGY RX200 S3 Specifications

General IconGeneral
Number of Processors2
StorageUp to 6 x 3.5" SAS/SATA HDD
RAID SupportRAID 0, 1
NetworkDual Gigabit Ethernet
Form Factor1U Rack
Power SupplyHot-plug redundant power supply

Related product manuals