RX200 S3 Operating Manual 77
Hot plug components Hot-pluggable hard disk drives
Removing the HDD module
If you want to replace a HDD module during operation, proceed as follows:
V CAUTION!
Only remove a HDD module during operation if the drive is not currently
being accessed. Observe the control LEDs for the corresponding HDD
module (see Hard disk drive control indicators in table on page page 48).
Ê If you want to remove a HDD module that is not defective, the drive must be
first set to offline via the software
(RAID controller configuration software).
Ê Now pull out the HDD module a few centimeters.
Ê Wait for at least 60 seconds.
I This period is necessary for the RAID controller to recognize that an
HDD module has been removed and for the hard disk drive to come
to a stop.
Ê Pull out the HDD module fully.
Ê Insert the new HDD module.
V CAUTION!
If you remove a HDD module and do not replace it with a new module,
insert a dummy module into the empty mounting location. Ensure that
the dummy module engages correctly in the slot.

Table of Contents

Other manuals for Fujitsu PRIMERGY RX200 S3

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu PRIMERGY RX200 S3 and is the answer not in the manual?

Fujitsu PRIMERGY RX200 S3 Specifications

General IconGeneral
Number of Processors2
StorageUp to 6 x 3.5" SAS/SATA HDD
RAID SupportRAID 0, 1
NetworkDual Gigabit Ethernet
Form Factor1U Rack
Power SupplyHot-plug redundant power supply

Related product manuals