1. INITIAL SETTINGS AND ADJUSTMENTS
1-15
3. Click the [Details] button and set the items referring to the table shown below.
Item Remarks
[Subsystem] Set this menu item to share the sensor data through HUB-3000. For
subsystem details, see page AP-3.
When sharing the sensor data: Set the value. Setting range: “A” to “Z”.
To not share the sensor data: Keep the default setting (“---”).
[System Alert ID] The identification number that assigned in the system is shown in this
field. Do not change the setting.
[Alert Information
Source]
Set the source of alert definition to show on the display when the alert
message is received in an ALF sentence.
[Alert Definition]: Show the alert definition registered to the proces-
sor unit.
[Alert Sentence]: Show the alert definition included in the ALF sen-
tence.
[ALF Text Infor-
mation]
Select the type of the 2/2 packet text information of ALF sentence.
[All Alert Name]: Select this item if all alert text is included in the 2/
2 packet of the ALF sentence. The text information for the 2/2 pack-
et of the ALF sentence is shown as the alert name in the alert list/
log.
[Remaining Alert Name]: Select this item if the alert text is divided
in 1/2 and 2/2 packets of the ALF sentence. The text information for
both the 1/2 and 2/2 packets of the ALF sentence is shown as the
alert name in the alert list/log.
[Decision Support]: Select this item if the alert details information
(Decision Support) is included in the 2/2 packet of the ALF sen-
tence. The text information for the 2/2 packet of the ALF sentence
is shown as the alert details in the alert list/log.
[Planning] Check the checkbox to assign the planning ECDIS. The planning EC-
DIS is a master unit to share the route data. For details of sharing the
route data, see the operator’s manual of the ECDIS.
Note: Alerts are not displayed on the planning ECDIS.