4. ALARMS
4-10
4.3.8 Other alarms
The following are the other alarms.
Menu item Description Remarks
Time The time alarm alerts you
when the preset time ar-
rives.
Time data required.
Low Battery The low battery alarm alerts
you when the input voltage
is the voltage setting or be-
low. The setting range is
8.5 to 32.0 V.
Max True Wind Speed The max true wind speed
alarm alerts you when the
true wind speed is the max
true wind setting or above.
Low True Wind Speed The low true wind speed
alarm alerts you when the
true wind speed is the low
true wind setting or below.
High APP Wind Angle The high APP wind angle
alarm alerts you when the
apparent wind angle from
starboard is the high appar-
ent wind angle setting or
above.
Set the starboard angle
with reference to the head-
ing.
Low APP Wind Angle The low APP wind angle
alarm alerts you when the
apparent wind angle from
port is the low apparent
wind angle setting or
above.
Set the port angle with ref-
erence to the heading.