You can also measure the distance from the x axis to the front brace as shown below. It doesn’t matter
exactly where you measure from, just so long as you’re consistent. Move the X axis to the back of the
machine and measure the points shown below.
If your right measurement is smaller, tighten the left idler
If your left measurement is smaller, tighten the right idler
12.7.3 Adjusting the Cable Tension
If Both Cables Are Loose: