99
Slide the clamp plate in. Note that the PEM nuts go on the bottom face.
Push the tube retention plate down into position (make sure the feed tube nut is still in the pocket) and
begin to thread the screws into the clamp plate.
Tighten the screws in an alternating pattern to make sure the print head is seated squarely.
If you unplugged them, reconnect the electrical connectors:
The green and white 2-pin connector goes to the thermistor (2 thin blue wires)
The red, black, & blue 3-pin connector go to the print head heater & bed probe (3-pin connector).
The 30mm fan and blower connectors are opposite so you can’t plug them into the wrong wiring