84
<Model Menu (Airplane/Glider Functions)>
●Selectthefunction name
and return to the Model
menu by touching the
RTN button.
<SensorTouch™>
AIL 3
(Chip Aileron)
AIL 4
(Chip Aileron)
AIL1
(Main Aileron)
AIL 2
(Main Aileron)
FLP 2
(Camber Flap)
FLP 1
(Camber Flap)
AIL to CMBFLP
[Corresponding model type]: Airplane/glider, 2 ailerons + 2 flaps or
more
This mix operates the camber flaps (FLP1/2)
in the aileron mode. When the aileron stick
is manipulated, the ailerons and camber flaps
perform aileron operation simultaneously to
signicantly improve the roll axis.
●Theaileronleft/rightmixingrateofeachapservo
can be independently adjusted.
●AnON/OFFswitchcanbeset.
●Linkingispossible:Linkthismixtoothermixes.
●Adjustmentofeach
apservo
Setting method
●Activate the function
Move the cursor to the [ACT] item and touch
the RTN button to switch to the data input
mode. Select the ACT mode by scrolling the
touch sensor.
*The display blinks.
Tou ch the RTN butto n t o a ctiva te the
function and return to the cursor mode. (ON
is displayed.)
When selecting a switch, move the cursor to
the [SW] item and touch the RTN button to
call the selection screen. Select the switch
and set its ON direction. (Always ON at "--"
setting)
*For a description of the switch selection method, see the
description at the back of this manual.
●Mixing rate adjustment
Move the cursor to the flap (FLP) 1~2 left
or right item according to the wing type
and touch the RTN button to switch to the
data input mode. Adjust the mixing rate
independently by scrolling the touch sensor.
Initialvalue:0%
Adjustmentrange:-120~+120%
*When the RTN button is touched for one second, the rate is
reset to the initial value.)
Touch the RTN button to end the adjustment
and return to the cursor mode.
●Link mode setting
When linking a mix, move the cursor to the
[LINK] item and touch the RTN button to
switch to the data input mode. Select the
ON mode by scrolling the touch sensor.
*The display blinks.
Touch the RTN button to set the link mode
and return to the cursor mode.
● Select [AIL to CMBFLP] at the Model
menu and access the setup screen
shown below by touching the RTN
*The display screen is an example. The actual
screen depends on the model type.
Scrolling
●Movingcursor
●Selectingmode
●Adjustingvalue
●Tonextpage
(Glider: Currently selected condition name)

Table of Contents

Other manuals for FUTABA 8FG

Related product manuals