5-4 PQM Power Quality Meter GE Power Management
5.2 A1 METERING 5 MONITORING
5
5.2.2 VOLTAGE
Figure 5–3: ACTUAL VALUES PAGE 1 METERING / VOLTAGE
]] ACTUAL VALUES
]] A1 METERING
] VOLTAGE
]
Van = 120 Vbn = 120
Vcn = 120 V
Iavg= 100 AMPS
Vavg= 120 V L-N
AVERAGE LINE
VOLTAGE = 208 V
VOLTAGE UNBALANCE =
0.0%
]] ACTUAL VALUES
]] A2 STATUS
ACTUAL
Van MIN = 100 V
12:00:00am 01/01/95
Vbn MIN = 100 V
12:00:00am 01/01/95
Vcn MIN = 100 V
12:00:00am 01/01/95
Vab MIN = 173 V
12:00:00am 01/01/95
Vbc MIN = 173 V
12:00:00am 01/01/95
Vca MIN = 173 V
12:00:00am 01/01/95
V U/B MIN = 0.0%
12:00:00am 01/01/95
Van MAX = 140 V
12:00:00am 01/01/95
Vbn MAX = 140 V
12:00:00am 01/01/95
Vcn MAX = 140 V
12:00:00am 01/01/95
Vab MAX = 242 V
12:00:00am 01/01/95
Vbc MAX = 242 V
12:00:00am 01/01/95
Vca MAX = 242 V
12:00:00am 01/01/95
V U/B MAX = 5.1%
12:00:00am 01/01/95