GE Power Management PQM Power Quality Meter 7-29
7 MODBUS COMMUNICATIONS 7.3 MODBUS MEMORY MAP
7
DEMAND
continued
0429 Time - Seconds of React Pwr Dmd Max --- --- --- F23 N/A
042A Date - Month/Day of React Pwr Dmd Max --- --- --- F24 N/A
042B Date - Year of React Pwr Dmd Max --- --- --- F25 N/A
042C Time - Hour/Min of App. Pwr Dmd Max --- --- --- F22 N/A
042D Time - Seconds of Apparent Pwr Dmd Max --- --- --- F23 N/A
042E Date - Month/Day of App. Pwr Dmd Max --- --- --- F24 N/A
042F Date - Year of Apparent Pwr Dmd Max --- --- --- F25 N/A
0430 Reserved
to
↓↓
043F Reserved
FREQUENCY 0440 Frequency --- --- 0.01 x Hz F1 N/A
0441 Frequency Minimum --- --- 0.01 x Hz F1 N/A
0442 Frequency Maximum --- --- 0.01 x Hz F1 N/A
0443 Time - Hours/Min of Frequency Max --- --- --- F22 N/A
0444 Time - Seconds of Frequency Max --- --- --- F23 N/A
0445 Date - Month/Day of Frequency Max --- --- --- F24 N/A
0446 Date - Year of Frequency Max --- --- --- F25 N/A
0447 Time - Hours/Min of Frequency Min --- --- --- F22 N/A
0448 Time - Seconds of Frequency Min --- --- --- F23 N/A
0449 Date - Month/Day of Frequency Min --- --- --- F24 N/A
044A Date - Year of Frequency Min --- --- --- F25 N/A
044B Reserved
to
↓↓
044F Reserved
PULSE INPUT
COUNTERS
0450 Pulse Input 1 (high) --- --- --- F3 N/A
0451 Pulse Input 1 (low) --- --- --- F3 N/A
0452 Pulse Input 2 (high) --- --- --- F3 N/A
0453 Pulse Input 2 (low) --- --- --- F3 N/A
0454 Pulse Input 3 (high) --- --- --- F3 N/A
0455 Pulse Input 3 (low) --- --- --- F3 N/A
0456 Pulse Input 4 (high) --- --- --- F3 N/A
0457 Pulse Input 4 (low) --- --- --- F3 N/A
ANALOG
INPUT
0458 Main/Alternate Analog Input (High) --- --- --- F3 N/A
0459 Main/Alternate Analog Input (low) --- --- --- F3 N/A
045A Reserved
to
↓↓
045F Reserved
PULSE INPUT
COUNTERS
0460 Totalized Pulse Input (high) --- --- --- F3 N/A
0461 Totalized Pulse Input (low) --- --- --- F3 N/A
0462 Pulse Count Cleared Time – Hours/Min --- --- --- F22 N/A
0463 Pulse Count Cleared Time – Seconds --- --- --- F23 N/A
0464 Pulse Count Cleared Date – Month/Day --- --- --- F24 N/A
0465 Pulse Count Cleared Date – Year --- --- --- F25 N/A
Table 7–10: PQM MEMORY MAP (Sheet 15 of 40)
GROUP ADDR
(HEX)
DESCRIPTION RANGE STEP
VALUE
UNITS and
SCALE
FORMAT FACTORY DEFAULT
Notes: * Data type depends on the Command Operation Code. ** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”. **** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Quality Meter Series and is the answer not in the manual?

GE Power Quality Meter Series Specifications

General IconGeneral
BrandGE
ModelPower Quality Meter Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals