7-34 PQM Power Quality Meter GE Power Management
7.3 MODBUS MEMORY MAP 7 MODBUS COMMUNICATIONS
7
WAVEFORM
CAPTURE
In
07C0 In Waveform Capture Scale Factor (high) --- --- A x 10000 F3 N/A
07C1 In Waveform Capture Scale Factor (low) --- --- A x 10000 F3 N/A
07C2 In Sample Buffer 1 --- --- ADC counts F2 N/A
07C3 In Sample Buffer 2 --- --- ADC counts F2 N/A
07C4 In Sample Buffer 3 --- --- ADC counts F2 N/A
07C5 In Sample Buffer 4 --- --- ADC counts F2 N/A
to
083E In Sample Buffer 125 --- --- ADC counts F2 N/A
083F In Sample Buffer 126 --- --- ADC counts F2 N/A
0840 In Sample Buffer 127 --- --- ADC counts F2 N/A
0841 In Sample Buffer 128 --- --- ADC counts F2 N/A
0842 Reserved
to
0847 Reserved
WAVEFORM
CAPTURE
Van
0848 Van Waveform Capture Scale Factor (high) --- --- V x 10000 F3 N/A
0849 Van Waveform Capture Scale Factor (low) --- --- V x 10000 F3 N/A
084A Van Sample Buffer 1 --- --- ADC counts F2 N/A
084B Van Sample Buffer 2 --- --- ADC counts F2 N/A
084C Van Sample Buffer 3 --- --- ADC counts F2 N/A
084D Van Sample Buffer 4 --- --- ADC counts F2 N/A
to
08C6 Van Sample Buffer 125 --- --- ADC counts F2 N/A
08C7 Van Sample Buffer 126 --- --- ADC counts F2 N/A
08C8 Van Sample Buffer 127 --- --- ADC counts F2 N/A
08C9 Van Sample Buffer 128 --- --- ADC counts F2 N/A
08CA Reserved
to
08CF Reserved
WAVEFORM
CAPTURE
Vbn
08D0 Vbn Waveform Capture Scale Factor (high) --- --- V x 10000 F3 N/A
08D1 Vbn Waveform Capture Scale Factor (low) --- --- V x 10000 F3 N/A
08D2 Vbn Sample Buffer 1 --- --- ADC counts F2 N/A
08D3 Vbn Sample Buffer 2 --- --- ADC counts F2 N/A
08D4 Vbn Sample Buffer 3 --- --- ADC counts F2 N/A
08D5 Vbn Sample Buffer 4 --- --- ADC counts F2 N/A
to
094E Vbn Sample Buffer 125 --- --- ADC counts F2 N/A
094F Vbn Sample Buffer 126 --- --- ADC counts F2 N/A
0950 Vbn Sample Buffer 127 --- --- ADC counts F2 N/A
0951 Vbn Sample Buffer 128 --- --- ADC counts F2 N/A
0952 Reserved
to
0957 Reserved
Table 7–10: PQM MEMORY MAP (Sheet 20 of 40)
GROUP ADDR
(HEX)
DESCRIPTION RANGE STEP
VALUE
UNITS and
SCALE
FORMAT FACTORY DEFAULT
Notes: * Data type depends on the Command Operation Code. ** Any valid Actual Values or Setpoints address.
*** Maximum Setpoint value represents “OFF”. **** Minimum Setpoint value represents “OFF”.
***** Maximum Setpoint value represents “UNLIMITED”.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE Power Quality Meter Series and is the answer not in the manual?

GE Power Quality Meter Series Specifications

General IconGeneral
BrandGE
ModelPower Quality Meter Series
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals