138 ADV200 • Quick start up guide
9.6.2 DC power supply
Input voltage ������������������������450 - 750 V
dc
Sizes
aDV200-...-Dc
ADV200-...-4-DC DC versions (Motor cos phi 0.9 @ 400
Vac
)
DC Input current (*)
Heavy duty (Arms) Light duty (Arms)
3185 39 48
3220 48 65
4300 65 80
4370 80 90
4450 90 125
5550 125 175
5750 175 210
5900 210 240
61100 240 290
61320 290 350
71600 370 430
72000 430 510
72500 510 710
73150 710 780
73551 780 850
400 kW 2 x 430 2 x 510
500 kW 2 x 510 2 x 710
630 kW 2 x 710 2 x 780
710 kW 2 x 780 2 x 850
900 kW 3 x 710 3 x 780
1 MW 3 x 780 3 x 850
(*) RMS input current in case of power from 6 impulse bridge.
Nota! Contact Gefran if an AFE200 series regenerative power supply is used.