ADV200 • Quick start up guide 175
10.6 Installation of optional cards
SLOT 1
SLOT 2
SLOT 3
EXP-SFTy-ADV
Up to three optional cards can be inserted in the three slots under the top cover:
• Slot 1
(1)
: dedicated to IO cards (EXP-IO-...-ADV , EXP-FL-XCAN-ADV)
• Slot 2: dedicated to Encoder cards (EXP-...-ADV)
and I/O cards
(2)
.
• Slot 3
(1)
:
dedicated to eld Bus cards (EXP-PDP-ADV, EXP-CAN-ADV, etc.) and
I/O cards
(2)
.
Note! (1) If managing 2 or 3 encoders, these slots can also be used for the encoder cards or the EXP-RES-...
resolver card, see section 10.5.1 for further details.
(2) On all of the slots on the control card, you can connect the three I/O expansion cards (*) dedicated
to the analog/digital I/O and to reading of temperature sensors PT100 / PT1000 / NI1000 / PTC / KTY84.
(*) EXP-IO-SENS-100-ADV card (recognized as I/O 8 at slot level), EXP-IO-SENS-1000-ADV card (recog-
nized as I/O 6 at slot level), and EXP-IO-D5R8-ADV card (recognized as I/O 7 at slot level).
EXP- SFTy-ADV card (models ADV-...SI): Integrated on board as the 4th option or integrated in the INT-
P-ADV power card (sizes ≥ 71600 and “L” HW version and above).
If an optional card is inserted in an incorrect Slot, the drive will send an error message.
The EXP-SFTy-ADV safety card can be installed and configured only in factory.