194 ADV200 • Quick start up guide
drive, one of the codes listed in Autotune (phasing), see chapter 8.2 Messages, is
shown.
Possible faults:
- faults in electric signals not detected with a “Speed fbk loss [22]” alarm
- error in the PAR 2008 Pole pairs parameter setting
- error in the PAR 2100 Encoder pulses parameter setting
Static phasing
Using this method, in which the motor cannot move, the encoder and motor data
cannot be cross-checked to verify the matching of parameters or count direction.
This condition must therefore be checked before launching the procedure.