erate to a stop. When parameter 11-41 is set to 1 operation will continue at the value of parameter 11-42 times
the last know frequency reference.
03-1X=27: Time function output
Output is controlled by timer function see parameter 03-37 and 03-38.
03-1X=28: Traverse operation UP status
Output is controlled by frequency wobbling operation; refer to Parameter group 19 for details.
03-1X=29: During Traverse operation status
Output is controlled by the acceleration period or frequency wobbling operation, refer to Parameter group 19 for
details.
03-1X=30: Motor 2 selected
Output is active when motor 2 is selected.
03-1X=31: Zero Servo Status (Position mode)
Output is active when Zero-servo operation is enabled and the load is locked into position.
03-1X=32: Communication control contacts
Communication location: 2507H,control by RY3 RY2 RY1.RY3 and RY2 will execute if DO1,DO2 and DO3 all
set communication control, and 2507H set 5(101)
03-1X=37: PID Feedback Loss Detection Output
When PID feedback loss occurs (refer to the setting of parameters 10-11~10-13), it performs the state of ON.
03-1X=38: Brake Release
The state of ON means release brake is active. Refer to parameters 03-41~03-42 for the details.
03-1X=39: Frequency Detection 1 (dedicated for Crane)
03-1X=40: Frequency Output
Refer to table 4.4.9 for the operation of frequency detection.
03-1X=41: Position Agree (Position Mode)
Position search is completed at position mode, then ON.
03-1X=45: PID Sleep
It will inform when PID sleep ON.
03-1X=50: Frequency Detection 3
03-1X=51: Frequency Detection 4
03-1X=52: Frequency Detection 5
03-1X=53: Frequency Detection 6
Please refer to Table 4.4.9 Frequency detection operation.
03-1X=54: Turn on short-circuit braking
Output terminal is closed when Turning on short-circuit braking.
Code Parameter Name / Range
03-13 Frequency detection Level
0.0~599.0 Hz
VDI100 • Instruction manual