HYDRAULIC SYSTEM
PROBLEM
POSSmLE
CAUSE REMEDY
Lift Arm will not lower Lift Cylinder Mechanical Lock engaged.
Raise Lift Arm and disengage Lock.
or raise.
Lift Solenoid Valve malfunctioning.
Check electrical connections
to
I
Solenoid. Repair or replace
as
needed.
Restraint Bar not lowered.
Lower Restraint Bar.
Seat or Restraint Bar Switch
Check electrical connections
to
the
I
malfunction. Switch. Replace Switches
as
needed.
1
I
I
Bucket drifts
Oil leaking past Tilt Cylinder Seals
Contact your Gehl Dealer for assistance.
downward with Tilt
(internal or external).
Control in
neutral.
Self-Leveling Valve
is
malfunctioning.
Repair or replace
as
needed.
'I
Leaking Hydraulic Hoses, Tubes, or Inspect Hoses and Tubes, tighten
I
fittings between Control Valve and
fittings
as
needed. Replace Hoses or
Cylinders. Tubes
as
needed.
No down pressure on
Control Valve in "Float" position. Take Control out
of
"Float" position.
Ii
the Bucket.
Tilt Cylinders are malfunctioning. Contact your Gehl Dealer for assistance.
Relief Valve in Control Valve not Contact your Gehl Dealer for assistance.
functioning properly. Squealing noise
should be evident.
Bucket does not level Self-Leveling Valve misadjusted or
Contact your Gehl Dealer for assistance.
on the lift cycle.
malfunctioning.
Bucket will not tilt,
Tilt Solenoid Valve malfunctioning.
Check electrical connections to Tilt
1
Lift Arms work
Solenoid and repair connections
as
properly.
needed.
If
Tilt Solenoid Valves are still
not functioning properly, contact your
Gehl Dealer.
Tilt Spool
in
Control Valve not actuated
Check Hose or tube connections
to
or leaking.
Valve.
High-Flow Auxiliary
Wiring to Switch or High-Flow
Check electrical connections.
Hydraulics fails to
Manifold Valve may be disconnected.
Reconnect or repair
as
needed.
turn on (DX units
only).
Seat or Restraint Bar Switch
Check electrical connections to the
malfunction.
Switch. Replace Switches
as
needed.
Solenoid on High-Flow Manifold Valve
Check electrical connections to
is malfunctioning.
Solenoid.
Attachment connected
Relief Valve on High-Flow Manifold Replace Relief Valve.
to High-Flow
Valve
is
malfunctioning.
Hydraulics stalls or
had low power (DX
units only).