CHANGE CHAINCASE OIL
(See Fig. 40)
Change the Chaincase with new oil after every 500
hours
of
operation,
or
annually.
Raise the Loader off the ground following the "Loader
Raising Procedure" located at the beginning
of
the
"Adjustments" Chapter
of
this manual.
1.
To gain access to the Drive Chains, remove the
Access Cover located on the outside, center
of
the
Chain case on both sides between the Wheels.
2.
Siphon or pump the old oil out
of
the Chaincase.
3.
Remove any debris, or sludge from the Chaincase.
4.
Refill the Chaincase with approximately 2 Gallons
(7.6 liters)
of
SAE lOW -30 motor oil.
5.
Replace Chaincase access covers using Oil Resistant
RTV or equivalent between the cover and the Chain-
case.
Follow "Loader Lowering Procedure" at the beginning
of
the "Adjustments" Chapter to return the loader to
the ground.
Fig. 40: Changing Chaincase Oil
1.
Chaincase Access
67