ProfiLux 4 Programming Guide
EN 2017-02-06 34
You start a feed pause by pressing the Esc key. If more than one feed pause is used, then the
appropriate feed pause has to be selected. The food pause can be interrupted by pressing
Esc again.
4.3 Internal Time
This function is used to display the internal clock (see also ->Clock). This function is only for
diagnostic purposes, settings cannot be made here.
4.4 Info & Support
After selecting this menu item, information about the software version, model and our
homepage is displayed one after the other (automatically after the lapse of a certain time or
by pushing a key).
4.5 Current
ProfiLux can control (current) pumps in a variety of ways; subsequent pumps are suitable for
control:
Pumps with an analog control signal input (mostly 1-10V-interface), such as those
from Tunze®, Royal Exclusiv® or Abyzz®, are connected to a 1-10V interface port of
the ProfiLux (for the connection to ProfiLux you need the corresponding accessory)
Pumps whose speed is adjustable via phase controlled modulation (therefore our
dimmable powerbar Powerbar2Dim is necessary)
EcoTech®-pumps of VorTech® (with our module VorTech-Controller)
Electronical external filter Professionel 3e® from Eheim® (with our module Eheim-
Controller)
Some low-voltage pumps, e.g. Koralia® from Hydor® (with our module PumpControl1)
Furthermore, non-controllable pumps can be switched via switchable sockets, see also
System-> Socket outlet function. These can then of course only be switched on or off but not
regulated.
The current control is organized in groups, one group consists of one or several pumps. The
settings can be made separately for each group and for each pump. The group settings
define the pumps belonging to the group, the operational mode and the time settings
(depending on the operational mode).
For each pump, settings such as wave duration, minimal or maximal speed or the behavior
during the feed pause can be set individually.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C