The New numbering must only be carried out if you have connected new devices to the
DALI bus.
Assign illumination This allows you to assign illumination to each connected DALI
device. This means that the brightness is set in the corresponding DALI device,
depending on the assigned illumination. After selecting this function, you can use
arrow up/ down to select which device you want to assign a illumination to. The
currently selected device is then operated with a brightness of 100%, all other devices
(or its associated lamps) are switched off. Confirm the selection with RETURN, then
you can Assign illumination? (arrow up/down, then RETURN again). After a short wait,
you can make another illumination assignment. When finished, press ESC.
8.12 Digital Input
If an Expansion card PLM-ADIN is available, there are 4 digital inputs as well as 2 analog
inputs. The state of a digital input can be used to directly switch a switch socket (see also
under System ->Socket outlet function) or to start or terminate a special function.
After selecting the digital input, its function can be set.
No action
This digital input does not have any special function.
Water change
This digital input starts the automatic water change. A second switching
impulse interrupts the automatic water change.
Maintenance
This digital input starts the maintenance mode. A second switching
impulse terminates the maintenance mode.
Feeding pause
This digital input starts the feeding pause. A second switching impulse
terminates the feed pause.
Storms
This digital input starts a thunderstorm.
8.13 myGHL
With the cloud-based service myGHL, we offer you an additional option for comfortably using
GHL products. To do so, you need a user account at www.myghl.com.
Before you create the account, please check whether the following prerequisites are met:
The latest firmware is installed on your ProfiLux 4. If not, perform a firmware update
(see the operating instructions).
Your ProfiLux 4 is assigned to your home network.

Table of Contents

Other manuals for GHL ProfiLux 4

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GHL ProfiLux 4 and is the answer not in the manual?

GHL ProfiLux 4 Specifications

General IconGeneral
ModelProfiLux 4
CategoryController
Power Supply12V DC
pH Ports2
Redox Ports1
Conductivity Ports1
Level Ports4
Digital Inputs4
12V Outputs4
Real-time clockYes, with battery backup
Digital Outputs4
ExpandableYes
ConnectivityUSB, Wi-Fi, LAN
DisplayGraphic LCD display
Expansion Slots4
Processor32-bit
Channels16
Operating Temperature0°C to 50°C